Volumetric Flow Detectors FP-5000 series New

FP-5000 series

Achieves accurate and wide range of mass flow measurement from small to large flow rate

In engine evaluations such as emission mode tests and transient tests for performance evaluation, the evaluation methods have been shifting from steady-state tests to transient tests. In the evaluation of fuel consumption, the requirement for evaluating the fuel consumption characteristics in transient duration has been increasing as well as the total fuel consumption for each mode. The FP-5000 series has achieved high pulse resolution and wide measurement range. It enables to detect changes in the flow rate effectively and responsively, and measure large flow rate. It can be used when the flow rate increases, such as when measuring alcohol fuel.

Features

 

1.Measuring even small amount of changes in the flow rate

Achieves 0.0005 mL/pulse resolution (when using FP-5130 series, up to 20 times of the existing models)


Instantaneous massflow measurement at starting engine

Integrated mass flow rate test during fuel injection by an injector

 

 Installation method of FP-5000 series Flow Detector

Installation method of FP-5000 series Flow Detector

 
 

2. Wide detector lineup supports from small to large flow rate

There are a wide range of flow detectors, which can be used for various applications from idling to WOT with a single detector.






 

3. Compact and space-saved design

A filter, the Volumetric Flow Detectors FP-5000 series, a flow detector, and a temperature/pressure sensor unit can be connected together, and achieved space saving.

 

4. Applicable to alcohol mixed fuel as standard

The flow detector is applicable to alcohol as standard.
The detector can be used without modification in the fuel flow measurement of engines that often use alcohol fuel.

System configuration

Figure of FP-5000 system configuration

 

Specifications

Standard typeSmall flow rate typeMedium flow rate typeLarge flow rate type
SeriesFP-5130 seriesFP-5140 seriesFP-5150 series
 FP-5130 seriesFP-5140 seriesFP-5150 series
 
Usable liquidGasoline, light oil, kerosene, alcohol, biofuel and general petroleum-based hydraulic oi (*1)
Measurement rangeFlow rateFP-5131/5132 : 0.05 to 60 L/h
FP-5133/5134 : 0.05 to 108 L/h
(*2)
FP-5141/5142 : 0.3 to 300 L/h
FP-5143/5144 : 0.3 to 600 L/h
FP-5151/5152 : 1 to 1440 L/h
AccuracyFlow rateWithin ±0.0009 L/h
(0.05 to 0.18 L/h )
Within ±0. 5 % of reading
(0.18 to 108 L/h) 
Within ±0.2% of readingWithin ±0. 5 % of reading
Pressure loss8 kPa or less
(at 40  L/h <gasoline>)
2 kPa or less
(at 60 L/h <gasoline>)
7.5 kPa or less
(at 500  L/h <light oil>)
Operating temperatureliquid0 to +65 °C0 to +65 °C0 to +65 °C
ambient0 to +65 °C0 to +65 °C0 to +65 °C
Inlet/ outlet portSizeIN: Rc3/8 (*3)
OUT: Rc3/8 (*3)
IN: Rc3/8 (*3)
OUT: Rc3/8(*3)
IN: Rc1/2
OUT: Rc1/2
Maximum operating pressure1 MPa1 MPa3.4 Mpa
Temperature/ pressure sensor unitEH-0830EH-0830EH-0850
Measurement rangeTemperature0 to +100 °C0 to +100 °C0 to +100 °C
Pressure0 to 1 MPa0 to 1 MPa0 to 1 MPa
AccuracyTemperaturePT100 Ω A classPT100 Ω A classPT100 Ω A class
Pressure±0.25 % F.S±0.25 % F.S±0.25 % F.S
Weight Approx. 3.5 kgApprox. 5.0 kgApprox. 13.5 kg
Accessary Instruction manual, line filter(EH-1130 or EH-1150), mounting bracket (Appropriate stand bracket for FP-5130/5140 series is supplied according to the selection of options.)  
Cable Optional: FP-0015(5m), FP-0016(10m), FP-0017(20m)
Applicable flow meterDigital flow meters:
FM-2500A/ DF-0400A (*not applicable to FP-5132, 5134, 5142, 5144 and 5152)
DF-2200(*not applicable to FP-5132, 5134, 5142, 5144, 5151 and 5152)
FM-3100/ FM-0311A
Filter/ Element
Alcohol applicableFilterEH-1130EH-1130EH-1150
ElementEH-0031AEH-0031EH-0051A

Please take note that the instantaneous flow rate may be varied;
1.if the inlet pressure is lower than the pressure loss.
2.if the outlet of the detector is open to the atmosphere.
(*1) Please contact to your nearest distributor.
(*2) Made-to order for the measurement range from 0.02 L/h. Please contact to your nearest distributor.
(*3) Option joint (SAE joint) is available. Please contact to your nearest distributor.

Option

ModelProduct nameContents
FM-0312FD additional connectorFor density input connection
FP-0015Signal cable for flow rate 5 mConnection cable for FM/DF series
FP-0016Signal cable for flow rate 10 m
FP-0017Signal cable for flow rate 20 m
FP-0025Temperature signal cable, 5 mConnection cable for FM/DF series
FP-0026Temperature signal cable, 10 m
FP-0027Temperature signal cable, 20 m
FP-0035Pressure signal cable, 5 mConnection cable for FM/DF series
FP-0036Pressure signal cable, 10 m
FP-0037Pressure signal cable, 20 m
FD-0011Density signal cable, 5 mConnection cable for FM series
FD-0012Density signal cable, 10 m
FD-0013Density signal cable, 15 m
EH-0830Temperature/pressure sensor units for FP-513X, FP-514XFor FP-513x, FP-514x
EH-0830 is a combination of EH-0081 and EH-0082
EH-0850Temperature/pressure sensor units for FP-515XFor FP-515x
EH-0731Mounting bracket for FP513x (single unit)1UNIT: Flow detector including line filter
EH-0732Mounting bracket for FP513x (2 units)2UNIT: Flow detector + Density meter or Temperature/pressure sensor unit
EH-0733Mounting bracket for FP513x (3 units)  3UNIT: Flow detector + Density meter + Temperature/pressure sensor unit
EH-0741Mounting bracket for FP514x (single unit)1UNIT : Flow detector including line filter
EH-0742Mounting bracket for FP514x (2 units)2UNIT: Flow detector + Density meter or Temperature/pressure sensor unit
EH-0743Mounting bracket for FP514x (3 units)  3UNIT: Flow detector + Density meter + Temperature/pressure sensor unit
EH-0730AStand bracket for FP513x/514xWhen using the stand, use at vibration of 9. 8 m/s2 or less.