Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Torque Station Pro TS-8700

Previous slide
Next slide

TS-8700 Torque Station Pro is torque measurement system for motor basic property with high precision and high response.
In combination with the motor torque detector MT series with the TH series torque detector, it is possible to perform high-precision, high-response motor torque measurement with up to 5.12 kHz sampling and ± 0.1 % of accuracy.
In addition, the high rigidity compact torque detector RH series (10 N・m/ 20 N・m) can be mounted on the MT series. It has achieved more highly accurate measurement with ±0.05 %/F.S.
This system is ideal for measuring torque fluctuations of motors on-board such as EPS motors.

  • Switching function of motor torque detector is built-in.
  • 2 channels as standard, up to 4 channels as options
  • Link function with OC-1300 series, OS-2000 series to help effective data processing from measurement to data organization
  • Various types of detectors (MT series) for the TS-8700 are available to support various motor characteristic measurement
  • Selectable from three series according to the purpose; for high speed rotation motor, large capacity motor, and torque ripple/cogging torque. There are three types including general, high performance and high precision, and 58 models in total.

Feature

High precision/ high response

When combined with the MT detector with the TH type torque detector, the torque measurement accuracy is ± 0.1% and the maximum sampling frequency is 5.12 kHz.
In addition, a new compact high-rigidity torque detector RH type can be mounted. The RH type torque detector (10 Nm / 20 Nm) is a torque detector that achieves high accuracy (± 0.05% F.S.) and high rigidity (4.5 times that of our existing models). It enables to measure torque fluctuations of motors in a higher frequency range with higher accuracy.

 

Temperature measurement*, temperature trigger measurement*

8ch temperature measurement with a T-type thermocouple, and temperature trigger function are optionally supported. They allow starting measurement automatically after warm-up operation.

 

Rotation angle measurement*, rotation angle sampling*

>Rotation angle and angle sampling are measured by using the pulses from encoder built-in a target motor. When an encoder is optionally added to the MT-82 T/M (except certain models) detector for cogging torque/torque ripple measurement, rotation angle and angle sampling can be measured in units of 0.1°.

Link function to OC-1300 series Graph creation software, and OS-2000 series Time series data analysis software

Data of measurement result can be transferred to OC-1300 series and OS-2000 series immediately by link function. You can transfer data of measurement results by the link button.
•Efficient and speedy report creation by using a template of OC-1300 series, such as a calibration certificate or others.
•Data evaluation in same time axis by OS-2000 series
The torque data measured by TS-8700 and the sound/vibration data recorded by DS-3000 can be evaluated in the same time axis on the OS-2000 series with this link function.
•Further analysis including FFT analysis can be performed as a secondary processing with the OS-2000 series.

Link function to DS-3000 series

Using this function, you can make measurement start/stop the DS-3000 synchronizing with those timing of TS-8700.
(Using EXT SEQUENCE2 as a DS synchronization signal can reduce the influence of the delay in recording start due to communication, compared to Link measurement on a LAN connection.)

Data communication with a power meter made by other company*

The measurement data of the following four specified power meters made by other companies can be saved digitally via LAN connection.

  • WT1800E, WT300E (WTViewerEfree*1Ver1.42 or later used) : made by YOKOGAWA ELECTRIC
  • PW3390, PW3337 (PW Communicator*2Ver1.7.0 or later used) :Made by HIOKI E.E. CORPORATION

*:Optionally available
*1:WTViewerEfree is registered trademark of YOKOGAWA ELECTRIC.
*2:PW Communicator is a registered trademark of HIOKI.E.E CORPORATION

 

 

 

 

 

 

 

 

 

Freely selectable system component

You can select devices according to the torque capacity to be tested or setting place. (Desktop type, Floor type stand with caster, XYZ stage, slide base, V block, L bracket etc.)
*Device to be selected may be limited depending on models or torque capacity. Please consult your nearest distributor or Ono Sokki sales office.

System of Link function to DS series (Data Station) •OS-2000 series (Time-series data analysis) •OC-1300 (Graph creation)

Data example

Can be used in a software for word processing or spreadsheet

Calculation display of efficiency
(Required current voltage detector separately)

Measurement data of Revolution-Torque characteristics

Measurement data of torque rippl

Application example

Measuring torque characteristic of DC motor

· The above example shows how to measure and display as graphs the characteristics of DC motor of torque, rotational speed, current, voltage. The efficiency performed by internal calculation also can be displayed.

· The MT-0710 series voltage/current detector (sold separately) is required.

System configuration

 

 

Measurement prodedure(Movie)

 

 

 

Measurement procedure of MT-8000 series/TS-8700

Overview specification

Measurement targetDC motor, AC motor (excluding stepping motor)
Measurement parameterTorque, rotation, voltage signal input data, temperature*,rotation angle*,power meter digital input*
Torque inputUse signals form Ono Sokki’s exclusive detector (MD/SS,TH/RH/TQ*) , external torque analog input*
Revolution inputUse signals form Ono Sokki’s MP-981 or RP series detectors
Analog input0 to ±10 V DC, 16 channels, 16 bit A/D   Connection cable: customer prepared
Temperature inputType T thermocouple*    T-type thermocouple: customer prepared
Measurement accuracyTorque**±0.05 %/F.S.(RH *,TQ *)
±0.1 %/F.S.(TH-1000/2000 *)
±0.2 %/F.S.(MD/SS、TH-3000/H)
Revolution speed**MT-84M/T/R series, MT-85M/T/R series ±0.02 %/F.S. ±1 count
MT-82T (excluding MT-82T15, MT-82T25 ±0.06 r/min
MT-82M, MT-82T15, MT-82T25,MT-82R15,MT-82R25 ±0.02 r/min
AnalogLinearity : ±0.1 %/F.S. Or less(1 second average), temperature drift:±0.01 %/F.S./°C
TemperatureConversion accuracy : within ±[0.5 % of span + 0.5 °C {thermosensitive element accuracy}]
Temperature drift : ±0.2 % or less of span to the change of 10 °C

*: Option
**: After N-0 compensation. 1-second averaged value
•Excluding the influence of fluctuation component comes from equipment component and resonance component including the measurement data-target

 

Computing equationFour arithmetic expression (The operation items can be defined by input signals and existing calculatd data.)
Measurement condition setting

Setting of torque detector, revolution detector

Control methodRevolution/torque
Measurement mode: Automatic/manual
Can be saved with a file name.
Measurement function◎Fixed value
measurement:
measurement time2 to 28,800 seconds
Number of data• SS/MD:512/1024/2048/4096/8192/angle Sample
• TH :2048/4096/8192/16384/32768/Sample
• TH high response (available when TS-0871 option installed)
   :10240/20480/40960/81920/163840/Sample
• RH/TQ (available when TS-0882 option installed)
   :10240/20480/40960/81920/163840/Sample
• EXT TRQ IN (available when TS-0873 option installed)
   :512/1024/2048/4096/8192/Sample
(Angle Sample: available only when manual operation (N) ,
and the measurement time is limited to 60 seconds or 120 seconds.)
◎Sweep measurementmeasurement timeDepending on the number of data.
512 : 2 to 1000 seconds
1024 : 4 to 1000 seconds
Number of data• SS/MD : 512 / 1024
• TH : 2048 / 4096
• TH high response (available when TS-0871 option installed) : 10240 / 20480
• RH/TQ (available when TS-0882 option installed) : 10240 / 20480
• EXT TRQ IN (available when TS-0873 option installed) : 512 / 1024
◎Step measurementNumber of steps2 to 128
Calculated automatically from the upper/lower limit torque or upper/ lower limit rotation speed and step width.
Step time5 to 100 seconds
◎Pattern measurementNumber of patterns1 to 128
Number of repeat times1 to 10
Shift time1 to 100 seconds
Monitor displayNumeric value display : Max. 100 items can be displayed simultaneously
Trend display:Time axis display
Graph display

Display by specifying X-axis, Y-axis from the measured data

Graph enlargement/reduction, specifying line color/line width, comment input, text display and text saving on the graph, cursor/peak search function, overlay display function, max. 16 files

Table displayList display of measured value, data edition function
ComparatorUpper/lower limit of selected items can be specified, max. 4 points to max. 6 items, display and output of judgment result
I/F for MT series detector2 channels, (4 channels as an option)
Saving measurement resultsData saved in an exclusive format or text format
Operating environment of a PC

PC specification that TS-8700 software can be operated on
•CPU Intel®™ Core®i5 or higher (recommended)
•4 GB or more of free memory (recommended)
•HDD/SSD 256 GB or more (recommended)
•Optical drive: Optical drive that can read CD-R for installation or update
•OS:Microsoft®Windows®10 Pro (64-bit) •English or Japanese version • Version 1803 or later

•Display: 1366 x 768 (full wide XGA) or more
•LAN port: Ethernet 100BASE-TX
* Not all the PC satisfying the above specifications are guaranteed to operate. Please supply a PC to check the operation.

Power requirementAC100 to 240 V± 10 %, 50/60 Hz
Power consumptionApprox.200 VA (AC100 V) or less
Isolation resistance10 MΩ or more (rated voltage DC 500 V)
Withstand voltageAC 1500 V for 1 minutes
Temperature/humidityOperating temperature range: + 5 to + 35 °C
Operating humidity range: + 30 to + 80 % RH (with no condensation)
Storage temperature range: − 10 to + 55 °C
Storage humidity range: + 30 to + 80 % RH (with no condensation)
Altitude condition etc.

Pollution degree: 2

Installation category: Category 2, indoor use
Max. altitude: 2000 m
With no condensation
Without no corrosive gas

Outer dimensions420 (W) x 149 (H) x 450 (D) mm or less
WeightApprox. 15 kg
Conforming standard
CE markingLow voltage Directive:2014/35/EU EN61010-1
EMC Directive:2014/30/EU EN61326-1 class 1 Industrial environment
RoHS Directive:2011/65/EU EN IEC 63000
FCCCRF47 Part15 Subpart B class A

MT8M: CE not supported
MT-0100 series, MT-071 series: RoHS not supported

AccessoryAC power cord, application CD-ROM, LAN cable (2m)
Others

*MT series detector and detection stand for motor etc are required separately.

* Adjustment fee is separately required for matching to the MT series detector.

Option

TS-0871
TH highly responsive samplingAdds the highly responsive sampling function of the TH detector (supports 5120 Hz)
TS-0872
Analog/pulse outputAdds torque/rotation speed analog output, and rotation speed pulse output function.
TS-0873
External torque/analog inputRequired when the torque control is used in the analog output of the torque detector.
TS-0874
Additional detector interfaceConnects four or more MT series torque detectors
TS-0875
Interface for BA-910ARequired when the BA-910 type power amplifier is used.
TS-0876
Temperature measurement/temperature trigger

Required for temperature measurement.

• Eight connectors (male) for sensor side are provided as standard.
TS-0877
Angle measurement/angle samplingAdds the angle sampling function of external encoders
•Cable side connector (R03-PB8M) is provided as standard.
TS-0878
Link to DS-3000Links to DS-3000 series made by Ono Sokki
TS-0881
Power meter digital communicationConnects to power meter made by other company via LAN, and loads the measurement values digitally.
TS-0882
Additional TQ/RH detectorIt can connect the TQ/RH series torque detectors.